| Model |
Indoor (50Hz) |
CS-UV12UKD-3 |
| Outdoor (50Hz) |
CU-UV12UKD-3 |
| Refrigerant Type |
R410A |
| Cooling Capacity |
(min-max) kW |
3.52 |
| (min-max)Btu/h |
12,000 |
| EER |
(min-max) Btu/hW |
11.01 |
| Electrical Data |
Voltage (V) |
230 |
| Running Current (A) |
5.0 |
| Power Input (W) |
1,090 |
| Moisture Removal |
L/h |
2.0 |
| Pt/h |
4.2 |
| Air Circulation |
Indoor m3/min (ft3/min) |
10.1 (356) |
| Outdoor m3/min (ft3/min) |
33.3 (1,180) |
| Noise Level |
Indoor (H/L/Q-Lo) (dB-A) |
41/29 |
| Outdoor (H / L) (dB-A) |
52 |
| Dimensions |
Height (mm) |
290 (542) |
| Height (inch) |
11-7/16 (21-11/32) |
| Width (mm) |
799 (780) |
| Width (inch) |
31-15/32 (30-23/32) |
| Depth (mm) |
197 (289) |
| Depth (inch) |
7-3/4 (11-13/32) |
| Net Weight |
kg |
8 (18) |
| lb |
29 (64) |
| Refrigerant Pipe Diameter |
Liquid Side (mm) |
ø 6.35 |
| Liquid Side (inch) |
1/4 |
| Gas Side (mm) |
ø 12.70 |
| Gas Side (inch) |
1/2 |
| Pipe Extension |
Chargeless Pipe Length (m) |
7.5 |
| Maximum Pipe Length (m) |
20 |
| Maximum Elevation Length (m) |
15 |
| Additional Refrigerant Gas* (g/m) |
10 |
| Power Supply |
Indoor |
| Cleaner Air |
nanoe-G |
No |
| Odour-Removing Function |
No |
| Removable, Washable Panel |
No |
| Comfort |
iAUTO-X |
No |
| iAUTO |
Yes |
| ECONAVI |
No |
| Temperature Wave |
No |
| AUTOCOMFORT |
No |
| Inverter Control |
No |
| Quiet Mode |
Yes |
| Soft Dry Operation Mode |
Yes |
| Personal Airflow Creation |
No |
| Airflow Direction Control (Up Down) |
Yes |
| Manual Horizontal Airflow Direction Control |
Yes |
| Convenience |
24-Hour Dual ON OFF Real Setting Timer |
No |
| 24-Hour ON OFF Real Setting Timer |
Yes |
| LCD Wireless Remote Control |
Yes |
| Wired Remote Control |
No (Optional) |
| Reliability |
Random Auto Restart (32 Restart Patterns) |
Yes |
| Blue Fin Condenser |
Yes |
| Long Piping (Numbers indicate the maximum pipe length) |
20m |
| Top-Panel Maintenance Access |
Yes |
| Self-Diagnostic Function |
No |
| NOTE |
Caution For CS-PV9/PV12/PV18/PV24/PV28TKH-1 (Important) Please do not use copper pipes that are less than 0.6mm in thickness.